The high-density fiber distribution cabinet is core infrastructure adapted to the harsh operating conditions of nuclear power plants and designed for highly reliable optical signal aggregation. Featuring high-density integration, strong environmental endurance and high safety redundancy, it is the key physical carrier for the stable operation of nuclear instrumentation & control (I&C) systems and data communication networks.
Пошаљи поруку Гет Прице
| Кабинет Материјал | Cold-Rolled Steel Sheet | Спољне димензије (мм) | КСНУМКС × КСНУМКС КСНУМКС × | ||||||
| Fiber Tray Capacity | 1,440–2,880 Cores | Тежина (кг) | |||||||
| Стандард Аццессориес | |||||||||
| Не. | Ime | Јединица | ком | Не. | Ime | Јединица | ком | ||
| 1 | Тело кабинета | Сет | 1 | 6 | Cable Fixing Assembly | Сет | 2 | ||
| 2 | Cable Ties (Nylon) | Pc | 60 | 7 | 1U Rack-Mount Splicing & Distribution Unit | Pc | 30 | ||
| 3 | Експанзиони анкер вијци | Pc | 4 | 8 | |||||
| 4 | Заштитна чаура за спајање | Pc | 2880 | 9 | |||||
| 5 | 1У Цабле Манагер | Pc | 15 | 10 | |||||
| Додатна опрема | |||||||||
| Не. | Ime | Јединица | ком | Не. | Ime | Јединица | ком | ||
| 1 | 12-Core Bundled SC Pigtail | Pc | 120 | 4 | СК адаптер | Pc | 1440 | ||
| 2 | 12-Core Bundled FC Pigtail | Pc | 120 | 5 | ФК адаптер | Pc | 1440 | ||
| 3 | 12-Core Bundled LC Pigtail | Pc | 240 | 6 | ЛЦ дуплекс адаптер | Pc | 1440 | ||
Operating Environment Indicators:
Оперативна температура: -КСНУМКС + ~ + КСНУМКС ℃
Температура складиштења: -40℃ ~ +85℃
Operating relative humidity: ≤85% (at +30℃)
Storage relative humidity: ≤90%–96% (at 40℃±2℃)
Atmospheric pressure: 70–106kPa
Типични сценарији примене:
Nuclear island I&C equipment room: centrally deployed in core controlled areas such as the HF building and the 220kV switchyard, it carries massive optical signal aggregation of the reactor I&C system, providing low-loss splicing, dispatching and full-link protection between trunk optical cables and I&C equipment, and completely avoiding the impact of strong electromagnetic interference on critical control signals.
Nuclear power data center equipment room: the high-density LC interface model meets 10G and 400G high-speed transmission requirements, supporting high-bandwidth data transmission for the nuclear power production management system and safety monitoring platform, with over 30% port redundancy reserved to meet expansion needs across the plant’s 60-year full life cycle.
Weak-current rooms of nuclear auxiliary buildings: it centrally manages the fiber links of subsystems such as video surveillance, security access control and environmental monitoring within the plant area, avoiding crossover confusion among links and greatly reducing troubleshooting time.
Напомена: Спецификације су подложне промени без претходне најаве ради побољшања производа.
Погодан је за различите сценарије потрошње енергије, као што су стамбене зграде и пословне зграде.
Посвећени смо пружању брзе, професионалне подршке како бисмо осигурали да ваше енергетске потребе увек буду задовољене уз највиши ниво услуге.
Ту смо да одговоримо на ваша питања и пружимо енергетска решења која најбоље одговарају вашим потребама.